Alfa Romeo OBD1 Trouble Codes
The following trouble codes are specific to Alfa Romeo.
- Click the table header to sort the table data by the respective column heading.
- Type keyword(s) in the table’s search box for a quick display of the searched data.
Code(s) | Description |
---|---|
00 | No failure type information |
01 | General electrical failure |
02 | General signal failure |
03 | Frequency modulated (FM)/pulse width modulated (PWM) signal failure |
04 | System internal failure |
05 | System programming failure |
06 | Algorithm based failure |
07 | Mechanical failure |
08 | Data bus signal/message failure |
09 | Component failure |
11 | Short circuit to earth |
12 | Short circuit to positive |
13 | Circuit open |
14 | Open circuit/short to earth |
15 | Open circuit/short to positive |
16 | Circuit voltage below threshold |
17 | Circuit voltage above threshold |
18 | Circuit current below threshold |
19 | Circuit current above threshold |
1A | Circuit resistance below threshold |
1B | Circuit resistance above threshold |
1C | Circuit voltage out of range |
1D | Circuit current out of range |
1E | Circuit resistance out of range |
1F | Circuit intermittent |
21 | Signal amplitude below minimum |
22 | Signal amplitude above maximum |
23 | Signal stuck low |
24 | Signal stuck high |
25 | Signal shape/waveform failure |
26 | Signal rate of change below threshold |
27 | Signal rate of change above threshold |
28 | Signal bias level out of range/zero adjustment failure |
29 | Signal invalid |
2A | Signal stuck in range |
2B | Signal cross-coupled |
2F | Signal erratic |
31 | No signal |
32 | Signal low time below minimum |
33 | Signal low time above maximum |
34 | Signal high time below minimum |
35 | Signal high time above maximum |
36 | Signal frequency too low |
37 | Signal frequency too high |
38 | Signal frequency incorrect |
39 | Signal has too few pulses |
3A | Signal has too many pulses |
41 | General checksum failure |
42 | General memory failure |
43 | Special memory failure |
44 | Data memory failure |
45 | Program memory failure |
46 | Calibration/parameter memory failure |
47 | Watchdog/safety micro-controller failure |
48 | Supervision software failure |
49 | Internal electronic failure |
4A | Incorrect component installed |
4B | Over-temperature condition |
51 | Component not programmed |
52 | Component program not activated |
53 | Component program disabled |
54 | Missing calibration |
55 | System not configured |
56 | Invalid/incompatible configuration |
57 | Invalid/incompatible software component |
61 | Signal calculation failure |
62 | Signal comparison failure |
63 | Circuit/component protection time-out |
64 | Signal plausibility failure |
65 | Signal has too few transitions/events |
66 | Signal has too many transitions/events |
67 | Signal incorrect after event |
68 | Event information |
71 | Actuator stuck |
72 | Actuator stuck open |
73 | Actuator stuck closed |
74 | Actuator slipping |
75 | Emergency position not reachable |
76 | Incorrect mounting position |
77 | Commanded position not reachable |
78 | Alignment or adjustment incorrect |
79 | Mechanical linkage failure |
7A | Fluid leak or seal failure |
7B | Low fluid level |
81 | Invalid serial data received |
82 | Alive/sequence counter incorrect/not updated |
83 | Value of signal protection calculation incorrect |
84 | Signal below allowable range |
85 | Signal above allowable range |
86 | Signal invalid |
87 | Missing message |
88 | Data bus off |
8F | Signal erratic |
91 | Component parameter out of range |
92 | Performance problem/malfunction |
93 | No operation |
94 | Unexpected component operation |
95 | Incorrect assembly |
96 | Component internal failure |
97 | Component or system operation obstructed or blocked |
98 | Component or system over-temperature condition |
9A | Component or system operating conditions |